Multiple application of three-dimensional soft kidney models with localized kidney cancer: A pilot study
|
01.08.2018 |
Glybochko P.
Rapoport L.
Alyaev Y.
Sirota E.
Bezrukov E.
Fiev D.
Byadretdinov I.
Bukatov M.
Letunovskiy A.
Korolev D.
|
Urologia |
|
3 |
Ссылка
AIM: To evaluate the effectiveness of three-dimensional printing application in urology for localized renal cancer treatment using three-dimensional printed soft models. MATERIALS AND METHODS: The study included five patients with kidney tumors. The patients were treated in the Urology Clinic of I.M. Sechenov First Moscow State Medical University from February 2016 to June 2017. Personalized three-dimensional printed models based on computed tomographic images were created. Five surgeons took part in a survey in which the utility of computed tomographic images versus three-dimensional printed models for presurgical planning was compared. A laparoscopic partial nephrectomy training using the developed three-dimensional printed models was performed by the same surgeons in a surgical training box. RESULTS: The patients underwent endoscopic surgery using laparoscopic access. The average time of surgery was 187 min. All the operations were performed with complete renal artery clamping. The average warm ischemia time was 19.5 min and the average blood loss was 170 mL. No conversions to open surgery or radical nephrectomy, and no postoperative complications and deaths were observed. All the surgical margins were negative. The tumors were morphologically identified as renal cell carcinoma in four cases and as oncocytoma in one case. CONCLUSION: The developed three-dimensional printed models allow one to evaluate the pathological anatomy of tumors more effectively. High similarity between three-dimensional models and native kidneys contribute to improvement of surgical skills necessary for partial nephrectomy. Training on the three-dimensional models also allows surgeons to facilitate selection of an optimal surgical tactics for each patient.
Читать
тезис
|
Nonlinear optical characteristics of albumin and collagen dispersions with single-walled carbon nanotubes
|
01.01.2018 |
Savelyev M.
Vasilevsky P.
Gerasimenko A.
Ichkitidze L.
Podgaetsky V.
Selishchev S.
|
Materials Physics and Mechanics |
|
1 |
Ссылка
© 2018, Peter the Great St. Petersburg Polytechnic University. The interaction of laser radiation with aqueous dispersion of only bovine serum albumin (BSA) 25 wt. %, only bovine collagen (BC) 2 wt. %, and 25 wt. % BSA with single-walled carbon nanotubes (SWCNTs) 0.3 wt. % and 2 wt. % BC with 0.3 wt.% SWCNT was studied. The beam was absorbed mainly by nanotubes, that confirmed by the small value of the nonlinear absorption coefficients for aqueous dispersed media with BSA 6 cm GW-1, as well as dispersion with BK 4 cm GW-1 and the large values of coefficients for these media with addition of SWCNTs, respectively 350 cm GW-1 and 70 cm GW-1. Determination of nonlinear optical parameters was obtained by the method of fixed sample location. Knowledge of the values of these parameters allowed calculating theoretical curve of Z-scan with open aperture what made possible to compare with the experimental data.
Читать
тезис
|